Correct storage conditions and packaging requirements for tetramethylguanidine to ensure stable product quality

Correct storage conditions and packaging requirements for Tetramethylguanidine (TMG) to ensure stable product quality

Introduction

Tetramethylguanidine (TMG), as a strongly alkaline organic compound, is widely used in various industrial and scientific research fields. In order to ensure TMG’s product quality is stable, correct storage conditions and packaging requirements are crucial. This article will introduce in detail the correct storage conditions and packaging requirements of TMG, and show the specific measures and effects in a table.

Basic properties of tetramethylguanidine

  • Chemical structure: The molecular formula is C6H14N4, containing four methyl substituents.
  • Physical properties: It is a colorless liquid at room temperature, with a boiling point of about 225°C and a density of about 0.97 g/cm³. It has good water solubility and organic solvent solubility.
  • Chemical Properties: It has strong alkalinity and nucleophilicity, can form stable salts with acids, and is more alkaline than commonly used organic bases such as triethylamine and DBU (1,8- Diazabicyclo[5.4.0]undec-7-ene).

Storage conditions of tetramethylguanidine

1. Temperature control
  • Temperature range: TMG should be stored in a cool, dry environment, and the temperature should be controlled between 10-25°C. High temperature will accelerate the volatilization and decomposition of TMG, affecting product quality.
  • Avoid high temperatures: Avoid exposing TMG to high temperatures, especially during the summer high temperature season, and appropriate cooling measures should be taken.
Storage conditions Specific requirements Reasons
Temperature range 10-25°C High temperature will accelerate volatilization and decomposition, affecting product quality
Avoid high temperatures Avoid exposure to high temperatures High temperatures may cause volatilization and decomposition
2. Humidity control
  • Humidity range: TMG should be stored in an environment with a relative humidity of less than 70%. A high-humidity environment will cause TMG to absorb moisture, affecting its purity and stability.
  • Moisture-proof measures: Use desiccant or dehumidification equipment to keep the storage environment dry.
Storage conditions Specific requirements Reasons
Humidity range Relative humidity < 70% High humidity environment will cause moisture absorption, affecting purity and stability
Moisture-proof measures Use desiccant or dehumidification equipment Keep the storage environment dry
3. Store away from light
  • Light protection requirements: TMG should be stored in a light-proof environment and avoid direct sunlight. Light will accelerate the decomposition of TMG and affect product quality.
  • Packaging materials: Use opaque packaging materials, such as dark glass bottles or aluminum foil bags, to reduce the impact of light.
Storage conditions Specific requirements Reasons
Light protection requirements Store in a dark environment Light will accelerate decomposition and affect product quality
Packaging materials Use opaque packaging materials Reduce the impact of light
4. Good ventilation
  • Ventilation requirements: The environment where TMG is stored should be well ventilated to avoid accumulation of volatile TMG gas and affect the health of operators.
  • Ventilation facilities: Install ventilation equipment, conduct regular inspection and maintenance, and ensure the normal operation of the ventilation system.
Storage conditions Specific requirements Reasons
Ventilation requirements Maintain good ventilation Avoid the accumulation of volatile gases and affect the health of operators
Ventilation facilities Install ventilation equipment, conduct regular inspection and maintenance Ensure ventilation system is functioning properly
5. Avoid contact with acidic substances
  • Isolation requirements: TMG should be stored away from acidic substances to avoid chemical reactions that may affect product quality.
  • Isolation measures: Use dedicated storage cabinets or areas to avoid mixing with acidic substances.
Storage conditions Specific requirements Reasons
Isolation requirements Store away from acidic substances Avoid chemical reactions that affect product quality
Isolation measures Use dedicated storage lockers or areas Avoid mixing with acidic substances

Packing requirements for tetramethylguanidine

1. Packaging materials
  • Container material: Use corrosion-resistant and well-sealed containers, such as glass bottles, stainless steel cans or plastic barrels. Avoid using materials that may react with TMG.
  • Sealing: Ensure that the packaging container is well sealed to prevent TMG from evaporating and external impurities from entering.
Packaging requirements Specific measures Reasons
Container material Use glass bottles, stainless steel cans or plastic buckets Avoid encounters with TMGReaction
Tight sealing Make sure the packaging container is tightly sealed Prevent volatilization and external impurities from entering
2. Packaging specifications
  • Packaging specifications: Choose the appropriate packaging specifications according to actual needs, such as 500 mL, 1 L, 5 L, 20 L, etc. Large packaging is suitable for large-scale production and storage, and small packaging is suitable for laboratory and small-scale use.
  • Label identification: Clearly mark the product name, batch number, production date, expiry date, storage conditions and other information on the packaging to facilitate management and use.
Packaging requirements Specific measures Reasons
Packaging specifications Choose appropriate packaging specifications Meet different usage needs
Tag ID Clearly label product information Easy to manage and use
3. Transportation requirements
  • Shipping container: Use a dedicated shipping container to ensure no leakage or damage during transportation.
  • Transportation conditions: Keep the temperature and humidity of the transportation environment within the appropriate range, and avoid high temperature and high humidity environments.
  • Transportation Marking: Clearly mark dangerous goods signs and transportation precautions on the transportation container to ensure transportation safety.
Transportation Requirements Specific measures Reasons
Shipping container Use dedicated shipping containers Ensure transportation safety
Shipping conditions Maintain appropriate temperature and humidity Avoid high temperature and high humidity environments
Shipping identification Mark dangerous goods signs and transportation precautions Ensure transportation safety

Specific application cases

1. Laboratory storage
  • Case Background: A research institution stores TMG in the laboratory and needs to ensure its quality and stability.
  • Specific application: The laboratory is equipped with a constant temperature and humidity storage cabinet, with the temperature controlled at 15-20°C and the relative humidity controlled at 50-60%. Store TMG in dark glass bottles away from light. Install ventilation equipment to maintain good ventilation.
  • Effectiveness evaluation: Through the above measures, the storage quality of TMG in the laboratory is stable, no volatilization and decomposition occur, and it meets the experimental needs.
Storage conditions Specific measures Effectiveness evaluation
Temperature control 15-20°C Stable quality
Humidity Control 50-60% Stable quality
Save in the dark Dark glass bottle Stable quality
Good ventilation Install ventilation equipment Stable quality
2. Industrial production and storage
  • Case Background: A chemical company uses a large amount of TMG in the production process and needs to ensure its quality and stability.
  • Specific application: The company has built a special storage warehouse with the temperature controlled at 10-25°C and the relative humidity controlled at 40-60%. Use stainless steel tanks to store TMG, ensuring a good seal. Install ventilation equipment to maintain good ventilation. Use desiccant and dehumidification equipment to keep the storage environment dry.
  • Effectiveness evaluation: Through the above measures, the storage quality of TMG during the production process is stable, no volatilization and decomposition occur, and it meets production needs.
Storage conditions Specific measures Effectiveness evaluation
Temperature control 10-25°C Stable quality
Humidity Control 40-60% Stable quality
Save in the dark Stainless steel tank Stable quality
Good ventilation Install ventilation equipment Stable quality
Drying measures Use desiccant and dehumidification equipment Stable quality

Conclusion

Tetramethylguanidine (TMG) is a highly efficient and multi-functional chemical. Correct storage conditions and packaging requirements are the key to ensuring stable product quality. By controlling storage conditions such as temperature, humidity, light protection, ventilation, and avoiding contact with acidic substances, as well as selecting appropriate packaging materials, specifications, and transportation requirements, the volatilization, decomposition, and contamination of TMG can be effectively prevented, ensuring its use in various application scenarios. performance and stability. Through the detailed analysis and specific application cases of this article, we hope that readers can have a comprehensive and profound understanding of the correct storage conditions and packaging requirements of TMG, and take corresponding measures in practical applications to ensure the stable quality of TMG.

References

  1. Chemical Safety Data Sheets: Sigma-Aldrich, 2018.
  2. Storage and Handling of Chemicals: American Chemical Society, 2019.
  3. Guidelines for the Safe Storage and Handling of Chemicals: Occupational Safety and Health Administration (OSHA), 2020.
  4. Safe Handling and Storage of Hazardous Chemicals: National Research Council, 2021.
  5. Chemical Storage and Compatibility Guide: Fisher Scientific, 2022.

Through these detailed introductions and discussions, we hope that readers can have a comprehensive and profound understanding of the correct storage conditions and packaging requirements of tetramethylguanidine, and take corresponding measures in practical applications to ensure the stable quality of TMG. Scientific evaluation and rational application are key to ensuring that these compounds fulfill their potential in a variety of application scenarios. Through comprehensive measures, we can unleash the value of TMG.

Extended reading:

Addocat 106/TEDA-L33B/DABCO POLYCAT

Dabco 33-S/Microporous catalyst

NT CAT BDMA

NT CAT PC-9

NT CAT ZR-50

4-Acryloylmorpholine

N-Acetylmorpholine

Toyocat DT strong foaming catalyst pentamethyldiethylenetriamine Tosoh

Toyocat DMCH Hard bubble catalyst for tertiary amine Tosoh

TEDA-L33B polyurethane amine catalyst Tosoh